  Datasheet File OCR Text:
 Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming)
Features
* * * * * * * * * * * * Single board design Synchronization function Low profile - 8.5 mm height Excellent co-planarity Input/output isolation: 1500 Vdc Convection cooling Low conducted and radiated EMI Output overcurrent protection Remote on/off (primary referenced) Wide output voltage trim adjust, positive or negative Operating temperature to 110C rd UL, CSA and EN/IEC60950 (3 ed.) approved
Applications
* * * * Distributed power architectures Telecommunications equipment LAN/WAN applications Data processing
Description
The RND series of converters are industry standard, 2" x 1" size, low profile, dual output, DC/DC converters intended for SMT placement and reflow soldering. The product provides on-board conversion of standard telecom, datacom and industrial input voltages to isolated low output voltages without the need for any additional cooling. Proprietary patented manufacturing process ensures optimal quality through full process automation. The converters are cost effective high performance alternatives to competing products on the market.
Selection Chart
Model Input voltage range, Vdc 38-75 36-75 Input current, max Adc 0.4 0.4 Output voltage, Vdc 3.27 5.20 12.0 12.0 Output rated current, Adc 1.0 1.0 0.42 0.42 Output ripple and noise, mVp-p 50 50 50 50 Efficiency, % 81 85
RND02ZGE-M6 RND0.8ZHH-M6
5-Nov-01
Rev 1.1 www.power-one.com
Page 1 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long term reliability and cause permanent damage to the converter. Specifications apply over specified input voltage, output load and temperature range, unless otherwise noted. Parameter Input voltage (Vin) Transient Input Voltage (Vint) Operating CaseTemp. (Tc) Storage Temperature (Ts) ON/OFF Control Voltage (Vrc) Conditions/Description Continuous Transient, 100ms All operating conditions Referenced to -Vin Min 36/38 -45 -55 -5 Max 75 100 110 125 16 Units Vdc Vdc C C Vdc
Environmental and Mechanical Specifications
Specifications apply over specified input voltage, output load and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Shock IEC68-2-27 100 g Sinusoidal Vibration IEC68-2-6 10 g Weight 0.6/17 oz/g Water Washing Standard process Yes MTBF Per Bellcore TR-NWT-000332 2,500 kHrs
Isolation Specifications
Specifications apply over specified input voltage, output load and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Insulation Safety Rating Operational Isolation Voltage (Vps) 1,500 Vdc Isolation Resistance (Rps) 10 MOhm Isolation Capacitance (Cps) 2,200 pF
Input Specifications
Specifications apply over specified input voltage, output load and temperature range, unless otherwise noted. Parameter Conditions/Description Min Nom Max Units Input Voltage (Vin) Continuous 36 (38) 48 75 Vdc Input Current when Shutdown Vin.Nom, Remote Control 3 mAdc activated Input Current No Load Vin.Nom, Io = 0 10 mAdc Turn-On Input Voltage 36-75 Vin Ramping Up, Io.Max 32 34.5 36 Vdc Turn-Off Input Voltage 36-75 Vin Ramping Down, Io.Max 30 33.5 35 Vdc Turn-On Input Voltage 38-75 Vin Ramping Up, Io.Max 34 36.5 38 Vdc Turn-Off Input Voltage 38-75 Vin Ramping Down, Io.Max 30 34.5 36 Vdc Turn-On Time To Output Regulation Band 250 400 ms After Remote Control 25 ms Rise Time 5 ms Input Reflected Ripple Current Vin.Max, Io.Max 30 mAp-p Input Capacitance 1.4 F 5-Nov-01 Rev 1.1 www.power-one.com Page 2 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Output Specifications
All specifications apply over input voltage, output load and temperature range, unless otherwise noted.
RND03ZGE: (Vo1) 5.2V/1.0A
Parameter Output Voltage Setpoint Accuracy Output Current * Line Regulation Load Regulation Cross Regulation Dynamic Regulation Peak Deviation Settling Time Output Voltage Ripple Admissible Load Cap. Output Current Limit Threshold Switching Frequency Temperature Coeff. Trim Range Vo Io Conditions/Description Vin.Nom, Io1 = 0.6A, Io2 = 0.9A, 25C Vin.Min to Vin.Max Vin.Min to Vin.Max, 50% Io.Max Vin.Nom, Io.Min to Io.Max Io1 =1.0A, Io2 Min to Max, measure Vo1 25-75% Io.Max load step change. to 1% error band Vin.Min to Vin.Max, Io.Min to Io Max, 20MHz Bandwidth Io.Max, Vin.Nom Vout 0.90 Vo.Nom, both outputs set to Icl Vin.Nom, Io.Max Io.Min to Io.Max, Vin.Min to Vin.Max Min 5.08 0.1 120 Nom 5.2 Max 5.24 1.0 50 220 130 200 300 100 2,200 150 380 4.43 0.02 5.95 Units Vdc Adc mV mV mV mV s mVp-p F %Io.Max kHz %Vo/C Vo
Vr Comax Icl Fs Tco Vt
50
110
RND03ZGE: (Vo2) 3.27V/1.0A
Parameter Output Voltage Setpoint Accuracy Output Current * Line Regulation Load Regulation Cross Regulation Dynamic Regulation Peak Deviation Settling Time Output Voltage Ripple Admissible Load Cap. Output Current Limit Threshold Switching Frequency Temperature Coeff. Trim Range Vo Io Conditions/Description Vin.Nom, Io1 = 0.6A, Io2 = 0.9A, 25C Vin.Min to Vin.Max Vin.Min to Vin.Max, 50% Io.Max Vin.Nom, Io.Min to Io.Max Io2 =1.0A, Io1 Min to Max, measure Vo2 25-75% Io.Max load step change. to 1% error band Vin.Min to Vin.Max, Io.Min to Io Max, 20MHz Bandwidth Io.Max, Vin.Nom Vout 0.90 Vo.Nom, both outputs set to Icl Vin.Nom, Io.Max Min 3.24 0.1 100 Nom 3.27 Max 3.3 1.0 40 210 90 200 300 100 3,300 150 380 0.02 3.8 Units Vdc Adc mV mV mV mV s mVp-p F %Io.Max kHz %Vo/C Vo
Vr Comax Icl Fs Tco Vt
50
110
Io.Min to Io.Max, Vin.Min to 2.8 Vin.Max * At IoutPage 3 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) RND02ZGE Characteristic curves
Cross Regulation Output 1 (+5V)
1 .2 1 1 .2 1 0.8 0.6 0.4 0.2 0 0 0.2 0.4 0.6 0.8 1 1 .2 0 0.2 0.4 0.6 0.8 1 1 .2
Cross Regulation Output 2 (+3.3V)
5V Ouptut Current (A)
0.8 0.6 0.4 0.2 0
3.3V Output Current (A)
5V Ouptut Current (A)
3.3V Output Current (A)
Efficiency Vs Load Efficiency
90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0.00 0.15 0.30 0.60 0.90 1.20 1.50 1.80 2.10 2.40 2.70 0 25 50 75 100% 3.00 Vin Min Vin Nom Vin Max
Iout (%)
5-Nov-01
Rev 1.1 www.power-one.com
Page 4 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Output Specifications
All specifications apply over input voltage, output load and temperature range, unless otherwise noted.
RND0.8ZHH: (Vo1) +12.0V/0.42A
Parameter Output Voltage Setpoint Accuracy Output Current * Line Regulation Load Regulation Cross Regulation Dynamic Regulation Peak Deviation Settling Time Output Voltage Ripple Admissible Load Cap. Output Current Limit Threshold Switching Frequency Temperature Coeff. Trim Range Vo Io Conditions/Description Vin.Nom, Io = 0.3A, 25C Vin.Min to Vin.Max Vin.Min to Vin.Max, 50% Io.Max Vin.Nom, Io.Min to Io.Max Io1 = 0.42A, Io2 Min to Max, measure Vo2 25-75% Io.Max load step change. to 1% error band Vin.Min to Vin.Max, Io.Min to Io Max, 20MHz Bandwidth Io.Max, Vin.Nom Vout 0.90 Vo.Nom, both outputs set to Icl Vin.Nom, Io.Max Io.Min to Io.Max, Vin.Min to Vin.Max Min 11.82 0.042 100 Nom 12.00 Max 12.18 0.42 90 170 60 400 300 100 100** 150 400 9.0 0.02 15.0 Units Vdc Adc mV mV mV mV s mVp-p F %Io.Max kHz %Vo/C Vo
Vr Comax Icl Fs Tco Vt
40
110
RND0.8ZHH: (Vo2) -12.0V/0.42A
Parameter Output Voltage Setpoint Accuracy Output Current * Line Regulation Load Regulation Cross Regulation Dynamic Regulation Peak Deviation Settling Time Output Voltage Ripple Admissible Load Cap. Output Current Limit Threshold Switching Frequency Temperature Coeff. Trim Range Vo Io Conditions/Description Vin.Nom, Io = 0.3A, 25C Vin.Min to Vin.Max Vin.Min to Vin.Max, 50% Io.Max Vin.Nom, Io.Min to Io.Max Io1 = 0.42A, Io2 Min to Max, measure Vo2 25-75% Io.Max load step change. to 1% error band Vin.Min to Vin.Max, Io.Min to Io Max, 20MHz Bandwidth Io.Max, Vin.Nom Vout 0.90 Vo.Nom, both outputs set to Icl Vin.Nom, Io.Max Min -11.82 0.042 100 Nom -12.00 Max -12.18 0.42 90 170 60 400 300 100 100** 150 400 0.02 -15.0 Units Vdc Adc mV mV mV mV s mVp-p F %Io.Max kHz %Vo/C Vo
Vr Comax Icl Fs Tco Vt
40
110
Io.Min to Io.Max, Vin.Min to -9.0 Vin.Max * At IoutPage 5 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) RND0.8ZHH Characteristic curves
Cross Regulation Output 1 (+12V)
0.45 0.4 +12V Ouptut Current (A) +12V Ouptut Current (A) 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 0.1 0.2 0.3 0.4 0.5 -12V Output Current (A) 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 0.1 0.2 0.3 0.4 0.5 -12V Output Current (A)
Cross Regulation Output 1 (-12V)
Efficiency 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
0.00 0.15 0.30 0.60 0.90 1.20 1.50
Efficiency Vs Load
Vin Min Vin Nom Vin Max
1.80 2.10 2.40 2.70 3.00
0
25
50
75
100%
Iout (%)
5-Nov-01
Rev 1.1 www.power-one.com
Page 6 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Feature Specifications
All specifications apply over input voltage, output load and temperature range, unless otherwise noted. Parameter Remote Control: Converter OFF Converter ON Sink Current Synchronization:* Frequency Range Conditions/Description RC pin is pulled low Voltage source or open circuit Vin=Vin.Nom Min -1.0 4.0 0.3 450 600 Nom Max 1.0 6 Units Vdc Vdc mAdc kHz
*
TTL compatible square wave on sync pin. Referenced to -Vin RND02ZGE does not have this feature.
Temperature Derating Curves
The derating curves below give an indication of the output power achievable with and without forced aircooling. However in the final application, in order to ensure the reliability of the unit, care must be taken to ensure the maximum case temperature is not exceeded under any conditions.
Output Power Vs Ambient Temp. and Airflow
120
100
Output Power (%)
80
60
400LFM (2 m/s) 200LFM (1 m/s)
40
0 LFM
20
0 0 10 20 30 40 50 60 70 80 90 100
Ambient Temp. (deg C)
5-Nov-01
Rev 1.1 www.power-one.com
110
Page 7 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Typical Application
KOhm RND0.8ZHH - Resistance required to decrease Vion
This series of converters does not require any external components for proper operation. However, if the distribution of the input voltage to the converter contains significant inductance, a capacitor across the input terminals may be required to stabilise the input voltage. A minimum of 1F, quality electrolytic / ceramic capacitor is recommended for this purpose. For output decoupling it is recommended to connect, directly across the output pins, a 1F ceramic capacitor (for 3.3V and 5V outputs) or a 0.27F ceramic capacitor (for 12V outputs).
2000 1500 1000 500 0 33.8 33.66 33.33 33 32 31
Voltage (Vion)
KOhm
RND0.8ZHH - Resistance required to increase Vion
Synchronization Feature
It is possible to synchronize the switching frequency of one or more converters to an external symmetrical clock signal. It is recommended that the signal be driven by a TTL compatible output. The rise time of the clock signal should be less than 10ns. If the synchronization feature is not used, it should be left open circuit.
1600 1400 1200 1000 800 600 400 200 0 34.3 34.8 35.2 37.5 40.5 42
Voltage (Vion)
Turn-On Input Voltage
An external resistor can program the input voltage at which the converter switches on. The voltage at which the unit switches off is typically 1V below the turn-on input voltage (Vion). The characteristic curves below shows the typical resistor values required to achieve adjustment of turn-on input voltage (Vion). To decrease Vion the resistor connected between pins 10 and 11. To increase Vion the resistor connected between pins 11 and 17. should be
KOhm
1 600 1 400 1 200 1 000 800 600 400 200 0
RND02ZGE - Resistance required to decrease Vion
35.6
35.4
35
34.2
33.5
33
Voltage (Vion)
KOhm
1600 1400 1200 1000 800 600 400 200 0
RND02ZGE - Resistance required to increase Vion
should
be
36.05
36.45
36.9
37.5
39.5
42
Voltage (Vion)
5-Nov-01
Rev 1.1 www.power-one.com
Page 8 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Output Voltage Trim
Note: For setting nominal output voltage pin 8 must be connected to pin 9. The trim feature allows the user to adjust the output voltage from the nominal. This can be used to accommodate a different requirement or to do production margin testing. Output voltage can be adjusted by an external resistor. If pin 8 and pin 9 are not connected together the output will decrease to a low value. To increase Vo a resistor should be connected between pin 8 / 9 and pin 17 ( -Vin). To decrease Vo, a resistor should be connected between pin 8 and 9 (NOR). To increase Vo: Radj = A x (B - Vd) / (Vd - Vo) k Where: Vd = Desired output voltage Vo = Nominal output voltage. To reduce Vo: Radj = C x (Vo - Vd) / (Vd - D) k Where: Vd = Desired output voltage Vo = Nominal output voltage.
Model RND02ZGE RND0.8ZHH A 0.5 0.572 B 3.92 16.126 C 2.0 2.243 D 2.56 8.295
Output Current Limiting
When the output is overloaded above the maximum output current rating, the voltage will start to reduce to maintain the output power to a safe level. In a condition of high overload or short-circuit where the output voltage is pulled below approximately 30% of Vo.Nom, the unit will enter a `Hiccup' mode of operation. Under this condition the unit will attempt to restart, approximately every 100ms until the overload has cleared.
Thermal Considerations
The converter is designed for natural or forced convection cooling. The output power of the converter is limited by the maximum case temperature (Tc). To ensure reliable long term operation of the converters, and to comply with safety agency requirements, Power-One limits maximum allowable case temperature (Tc) to 110C (see Mechanical Drawings).
Remote Control Feature
The remote control pin functions as a normal soft shutdown. It is referenced to the -Vin pin. With positive logic, when the remote control pin is pulled low, the output is turned off and the unit goes into a very low input power mode. An open collector switch is recommended to control the voltage between the remote control pin and the -Vin pin of the converter. The remote control pin is pulled up internally, so no external voltage source is required. The user should avoid connecting a resistor between the remote control pin and the +Vin pin. The user must take care to ensure that the pin reference for the control is connected close to the -Vin pin. The control signal must not be referenced ahead of EMI filtering, or remotely from the unit. If the remote control pin is not used, it can be left floating.
Notes: 1. When the output voltage is trimmed up, the output power from the converter must not exceed its maximum rating. This is determined by measuring the output voltage on the output pins, and multiplying it by the output current. 2. The trim feature allows the generation of additional standard voltages such as 15V from the 12V model.
Parallel Operation
Paralleling of two converters is possible by direct connection of the output voltage terminal pins. The load regulation characteristic is designed to facilitate current sharing (typically 20%). 5-Nov-01
Rev 1.1 www.power-one.com
Page 9 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Safety Considerations
These converters feature 1500 Volt DC isolation from input to output. The input to output resistance is greater than 10MOhm. These converters are provided with Operational Insulation between input and output circuits according to EN60950 / UL1950 / CSA60950-00. Nevertheless, if the system using the converter needs to receive safety agency approval, certain rules must be followed in the design of the system. In particular, all of the creepage and clearance requirements of the end-use safety requirements must be observed. These documents include UL60950, CSA60950-00 and EN60950, although specific applications may have additional requirements. In order for the output of the converter to be considered as SELV (Safety Extra Low Voltage) or TNV-1, according to EN60950 / UL1950 / CSA60950-00, one of the following requirements must be met in the system design: * The converter has no internal fuse. An external fuse must be provided to protect the system from catastrophic failure. A fuse with a rating not greater than 2.0A is recommended. The user can select a lower rating fuse based upon the inrush transient and the maximum input current of the converter, which occurs at the minimum input voltage. Both input traces and the chassis ground trace (if applicable) must be capable of conducting a current of 1.5 times the value of the fuse without opening. The fuse must not be placed in the grounded input line, if any. * If the voltage source feeding the module is SELV, the output of the converter is considered SELV and may be grounded or ungrounded. * The circuitry of the converter may generate transients, which exceed the input voltage. Even if the input voltage is SELV (<60V) the components on the primary side of the converter may have to be considered as hazardous. A safety interlock may be needed to prevent the user from accessing the converter while operational. 5-Nov-01
EMC Specifications
Conducted Noise: The converters meet the requirements of EN55022, CISPR22 and FCC CFR title 47 part 15 Sub-part J - Conducted (conducted noise on the input terminals) without any external components. The results for this solution are displayed below. To meet level B for the above standards it is necessary to fit a 3.3F ceramic capacitor across the input terminals.
dbV
80 70 60 50 40 30 20 1 0 0 EN55022 A A V.
Conducted EMI (Input Term inals)
EN55022 A QP .
0.1 1.E+05
1 1.E+06
FREQ (MHz)
10 1.E+07
30
1.E+08
Electromagnetic Susceptibility:
Standard Electrostatic Discharge EN61000-4-2 Electromagnetic Field EN61000-4-3 Electrical Fast Transient EN61000-4-4 Conducted Disturbances EN61000-4-6 Applied Stress 2KV to pins 3V/m 2000 Vp to input 3Vrms to input Class Level 1 2 3 Performance Outcome * B A B
2
B
* A denotes normal operation, no deviation from specification. B denotes temporary deviation from specification is possible.
Rev 1.1 www.power-one.com
Page 10 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming) Surface Mount Assembly
Soldering: The following instructions must be observed when soldering the unit. Failure to observe these instructions may result in failure or significant degradation of the module performance. PowerOne will not honor any warranty claims arising from failure to observe these instructions. This product is approved for forced convection reflow soldering only. The curves below define the maximum peak reflow temperature permissible measured on Pins 1 and 10 of the converter. The lead-frame is constructed for a high temperature glass filled, UL94V0 flame retardant, diallyl ortho-phthalate moulding compound commonly used for packaging of electronics components. It has passed NASA outgassing tests and is certified to MIL-M-14. The coefficient of thermal expansion is equivalent to FR4. The gull wing leads are formed to ensure optimal solder joint strength and structure. Furthermore they facilitate visual inspection (manual or automatic). The leads are formed from a 97% Cu alloy plated with Cu and Sn 90. This material is commonly used in the manufacture of integrated circuits. It has good corrosion resistance and exhibits the nobility inherent to all high copper alloys. Unlike brasses, this material is essentially immune to stress corrosion cracking. It also exhibits excellent solderability. It is readily wetted by solders and performs well in standard solderability tests. (Dip of Class II or better). The product is manufactured with a patented process, which is fully automated, and `in-line'. This ensures that there is no contamination or mechanical stress on the lead-frame so that the co planarity and solderability are maintained. The product is shipped in JEDEC trays to guarantee preservation of the co-planarity and enable fully automated assembly in the final application. .
300 250 200 150 100 50 0
120 160 200 240 40 80 0
Max. temp. on pins 1 and 10 during reflow soldering (deg C)
Peak Temperature (See fig below)
tp
280
320
360
400
Time (s)
Restriction curve above 215C Peak temp. at pins 1 and 10 (C) 245 240 235 230 225 220 215 210 205 200 10 20 30 40 50 60 tp (s)
Pick & Place Assembly: The product is designed with a large flat area in the center of the top surface to serve as a pick up point for automated vacuum pick and place equipment. The `open board' construction of the unit ensures that weight is kept to a minimum. However due to the relatively large size of the component, a large nozzle (> 4.0mm, depending on vacuum pressure) is recommended for picking and placing. The unit may also be automatically handled using `odd-form' placement equipment, with mechanical grippers. For this type of equipment the end edges of the device, which have no leads and also feature the greatest dimensional accuracy, should be used as pick-up points.
5-Nov-01
Rev 1.1 www.power-one.com
Page 11 of 14
440
190 - 450 s
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming)
Mechanical Drawing
Note:- mm[inches] Tolerances: 0.5-10 0.1 10-100 0.2
47.4 [1.866] 7.4 [0.291]
28 [1.102]
25.4 [1]
Pin 1
Tc
&
2.6 [0.102]
3.7 [0.146]
Pick up point Top View
8.5 [0.335]
45.6 [1.795]
Height Profile
5-Nov-01 Rev 1.1 www.power-one.com Page 12 of 14
2.9 [0.114]
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming)
18
17
16
15
14
13
12
11
10
2.8 [0.11]
24 [0.945]
29.6 [1.165]
1
2
3
4
5
6
7
8
9
5 [0.197] 40 [1.575]
3.6 [0.142]
Recommended land pattern
Tray pickup point
JEDEC TRAY
5-Nov-01 Rev 1.1 www.power-one.com Page 13 of 14
Product Specifications RND Series: 8-10W DC/DC Converters Nov 2001 38-75V Input 3.3V & 5.0V, 12V Dual Outputs (15V, available with trimming)
Pin-Out
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Designation Vout1 Rtn Vout2 NC NC NC Sync Trim NOR TOA RC NC NC NC NC NC -Vin +Vin Function Output voltage 1 Output voltage return Output voltage 2 Not connected Not connected Not connected Synchronization Input Output voltage adjust. Note: - To set nominal output voltage connect pins 8 and 9 together Connection for nominal output voltage Turn-on/off input voltage adjust Remote control. Pull low to turn unit off Not connected Not connected Not connected Not connected Not connected Negative input voltage Positive input voltage Reference Secondary Secondary Secondary Secondary Secondary Primary Primary Primary Primary Primary Primary Primary Primary Primary Primary Primary Primary Primary
Ordering Information
Options Surface Mount Version, shipped in JEDEC Tray Through hole (leaded) version. Suffixes to part number Suffix "-M6". Consult factory for availability.
Notes
1. 2. 3. Consult factory for the complete list of available options. Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. Specifications are subject to change without notice.
5-Nov-01
Rev 1.1 www.power-one.com
Page 14 of 14


▲Up To Search▲   

 
Price & Availability of RND08ZHH-M6

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X